Related Experiment Video
Updated: Apr 22, 2026

Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation
G Lima-Oliveira1, G L Salvagno, E Danese
1Laboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona, Verona, Italy; Post-Graduate Program of Pharmaceutical Sciences, Department of Clinical Analyses, Federal University of Parana, Curitiba, Parana, Brazil.
Introduction:
The potential cross-contamination of additives between primary blood tubes is a well-known problem during sample collection. The aim of this study was to assess the impact of citrated blood contamination with different amounts of dipotassium ethylenediaminetetraacetic (K2 EDTA blood) on activated partial thromboplastin time (APTT), prothrombin time (PT), and fibrinogen.
Methods:
Blood was collected from 15 ostensibly healthy volunteers into four 0.109 m citrate blood tubes followed by one K2 EDTA blood tube. The citrate tubes of each subject were pooled and divided in five aliquots. The whole blood of the K2 EDTA tube was then added in scalar amounts to autologous citrated blood aliquots, to obtain K2 EDTA contamination ranging from 0% to 43%, and thus mimic potential pre-analytical contamination.
Results:
A statistically and clinically significant prolongation was observed for both APTT and PT between 29% and 43% K2 EDTA contamination, whereas the decrease of fibrinogen values became statistically and clinically significant at 43% K2 EDTA contamination.
Conclusion:
The results of this investigation show that contamination of citrated blood with as much as 29% of K2 EDTA blood generates a significant bias in results of routine clotting assays. This has serious implications for patient safety and management.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
EDTA: Auxiliary Complexing Reagents
Complexometric EDTA Titration Curves
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
EDTA: Indirect and Alkalimetric Titration
EDTA: Chemistry and Properties

