Cardiovascular MR imaging at 3 T: opportunities, challenges, and solutions
Prabhakar Rajiah1, Michael A Bolen
1From the Cardiothoracic Imaging Section, Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University School of Medicine, 11100 Euclid Ave, Cleveland, OH 44106 (P.R.); and Cardiovascular Imaging Laboratory, Imaging Institute, Cleveland Clinic Foundation, Cleveland, Ohio (M.A.B.).
Abstract:
Although 3-T magnetic resonance (MR) imaging is well established in neuroradiology and musculoskeletal imaging, it is in the nascent stages in cardiovascular imaging applications, and there is limited literature on this topic. The primary advantage of 3 T over 1.5 T is a higher signal-to-noise ratio (SNR), which can be used as such or traded off to improve spatial or temporal resolution and decrease acquisition time. However, the actual gain in SNR is limited by other factors and modifications in sequences adapted for use at 3 T. Higher resonance frequencies result in improved spectral resolution, which is beneficial for fat suppression and spectroscopy. The higher T1 values of tissues at 3 T aid in myocardial tagging, angiography, and perfusion and delayed-enhancement sequences. However, there are substantial challenges with 3-T cardiac MR imaging, including higher magnetic field and radiofrequency inhomogeneities and susceptibility effects, which diminish image quality. Off-resonance artifacts are particularly challenging, especially with steady-state free precession sequences. These artifacts can be managed by using higher-order shimming, frequency scouts, or low repetition times. B1 inhomogeneities can be managed by using radiofrequency shimming, multitransmit coils, or adiabatic pulses. Chemical shifts are also increased at 3 T. The higher radiofrequency results in higher radiofrequency deposition power and a higher specific absorption rate. MR angiography, dynamic first-pass perfusion sequences, myocardial tagging, and MR spectroscopy are more effective at 3 T, whereas delayed-enhancement, flow quantification, and black-blood sequences are comparable at 1.5 T and 3 T. Knowledge of the relevant physics helps in identifying artifacts and modifying sequences to optimize image quality. Online supplemental material is available for this article.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...