A study on the necessity of kV-CBCT imaging compared to kV-orthogonal portal imaging based on setup errors: considering other socioeconomical factors
Related Experiment Video
Updated: Apr 22, 2026

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
Published on: October 27, 2023
Om Prakash Gurjar1, Surendra Prasad Mishra, Virendra Bhandari
1Department of Physics, Mewar University, Chittorgarh, Rajasthan; Roentgen - SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Science, Indore, Madhya Pradesh, India.
Purpose:
Evaluation of setup accuracy in kV-orthogonal portal imaging (OPI)-based and kV-CBCT-based radiotherapy treatment and to find out the necessity of cone-beam computed tomography (CBCT) compared to OPI.
Materials And Methods:
A retrospective study was carried out on 30 patients, who received radiotherapy to the Brain, Head and Neck, and Pelvis. In the OPI technique, anterior-posterior and right-lateral portal images were taken by the On Board Imaging (OBI) system and were superimposed on the reference images. Similarly, in the kV-CBCT technique, CBCT was performed by the OBI system and CBCT images were superimposed on the reference CT images. A total of 150 comparison sets of kV-OPI and kV-CBCT images were analyzed and evaluated. Shifts in the Lateral, Longitudinal, and Vertical directions were noted in both techniques. The iso displacement vector (IDV) was calculated for all imaging.
Results:
The mean IDV (in cm) are found to be 0.3395 (SD: 0.1477) and 0.3088 (SD: 0.1593) in cases of the brain, 0.4266 (SD: 0.1511) and 0.3666 (SD: 0.1533) in cases of the head and neck, and 1.0339 (SD: 0.5893) and 0.9498 (SD: 0.6047) in cases of the pelvis for the CBCT and OPI techniques, respectively. The P values were 0.3201, 0.0515, and 0.4829 for the brain, head and neck, and pelvic cases, respectively.
Conclusions:
There is statistically no significant difference between both the imaging techniques. As the dose delivered by the CBCT technique is higher than that by the OPI technique, from the socioeconomical and radiation safety point of view, the OPI technique is possibly better than the CBCT technique. Hence, it can be concluded that CBCT is not a mandatory technique compared to the OPI technique in routine brain, head and neck, and pelvic cases, except in those cases where better information about interfraction movements of soft tissue is necessarily required for positioning of the target, as is the case in prostate carcinoma.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies I: Kidney, Ureter, and Bladder Studies

