Blinded observer evaluation of distal skin temperature for predicting lateral infraclavicular block success
Semera Asghar1, Kai H W Lange, Lars H Lundstrøm
1From the Department of Anaesthesiology and Intensive Care, Nordsjællands Hospital, Copenhagen University, Hillerød, Denmark.
Background:
Changes in digit skin temperature may be used to predict and determine upper limb nerve block success. We investigated whether a temperature difference between the blocked and the nonblocked hands, simply registered by touching the skin of the 5th and 2nd digit was valid and reliable as a diagnostic test for predicting a successful lateral infraclavicular block.
Methods:
Blinded observers investigated temperature difference between the blocked and the nonblocked hands of 40 patients. Sensitivity, specificity, and predictive values of a positive and a negative test were estimated for evaluating the validity of a temperature difference for predicting a successful lateral infraclavicular block defined by sensory and motor block of all 4 major nerves (musculocutaneous, radial, ulnar, and median nerves). κ statistics of interobserver agreement were used for evaluating the reliability of the test.
Results:
As a stand-alone test, a temperature difference between the corresponding 2nd and 5th digits of the blocked and the nonblocked hands predicted a successful block with a sensitivity of 92% (95 % confidence interval (CI), 83%-97%) and with a predictive value of a positive test of 95% (CI, 86%-98%). Fleiss κ for multiple observers was 0.74, (CI, 0.61-0.87) for the 5th digit and 0.87 (CI, 0.73-0.998) for the 2nd digit, respectively.
Conclusions:
We found that a qualitative difference in skin temperature between the blocked and nonblocked hands, measured distally on the 2nd and 5th digits, was a valid and reliable diagnostic test for predicting successful lateral infraclavicular block.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...