Non-invasive ventilation: evaluation of CO2 washout by intentional leaking in three recent oronasal masks. A pilot
C Medrinal1, G Prieur, O Contal
1Groupe Hospitalier du Havre, Service de Pneumologie, Montivilliers, France - medrinal.clement.mk@gmail.com.
Background:
Many types of interfaces with intentional leaks exist for Non Invasive Ventilation. The purpose of intentional leaks is to remove CO2 from the interface, however the calibration does not allow a sufficiently large flow and rebreathing of CO2 can occur. The aim of this study was to compare the CO2 rinsing capacities of three new generation oronasal masks with intentional leaks (A: Quattro®, [Resmed]; B: Amara® [Respironics]; C: Forma® [Fisher&Paykel]) in healthy subjects.
Methods:
Seventeen healthy volunteers were included in this prospective cross-sectional, randomized, double-blinded trial. Each subject underwent ventilation with a home ventilator (IPAP: 14 cmH2O; EPAP: 4 cmH2O) with each mask consecutively. Transcutaneous capnography (PtcCO2) recordings were carried out throughout the trial and ventilator data (tidal volume, respiratory rate, minute ventilation and unintentional leaks) were also analyzed. Mask comfort was assessed using a visual analog scale (0 to 10).
Results:
The results showed no differences in PtcCO2 between masks (P=0.82). There were no significant differences in respiratory parameters (tidal volume, P=0.79; respiratory rate, P=0.65; minute ventilation, P=0.12) between masks. The rate of unintentional leaks were significantly lower for Mask A (P=0.016). Subjects rated Mask A and Mask C as more comfortable than Mask B (P=0.041).
Conclusion:
There was no effect of mask on PtcCO2 in healthy subjects. The mask with the highest comfort rating had not the lowest rate of unintentional leaks.
More Related Videos
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...