Long-term stability monitoring of pH reference materials using primary pH method
Fabiano Barbieri Gonzaga1, Júlio Cesar Dias
1Chemical Metrology Division, National Institute of Metrology, Quality and Technology (INMETRO), Av. Nossa Senhora das Graças, 50, Xerém, 25250-020, Duque de Caxias, RJ, Brazil, fbgonzaga@inmetro.gov.br.
Abstract:
This work presents the results from a series of stability studies for some batches of different aqueous pH reference materials, packed in high-density polyethylene (HDPE) bottles, taking primary pH measurements over long periods (time lengths from 18.4 to 21.0 months). The results obtained over time for acid and neutral buffer solutions (nominal pH values of 1.68, 4.00, and 6.86 at 25 °C), considering their uncertainties, were statistically similar, demonstrating the high stability of these materials. On the other hand, for the alkaline buffer solutions (nominal pH values of 9.18 and 10.01 at 25 °C), there was a clear decrease in the results over time, with pH variation rates around -8.5 × 10(-4) per month. The results showed that reference materials of the acid and neutral buffer solutions can be easily provided with small uncertainty values and long shelf lives in simple HDPE bottles closed under air atmosphere, whereas reference materials of the alkaline buffer solutions must have more limited shelf lives and higher uncertainty values (taking into account the pH decrease over time) or must be provided in special packaging (such as ampoules) to prevent carbon dioxide interference.
Related Concept Videos
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Indicators
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Data Validation
Key parameters for method validation include:
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Therapeutic Drug Monitoring: Drug Analysis Methods