Image-derived input function with factor analysis and a-priori information
Urban Simončič1, Paolo Zanotti-Fregonara
1aJožef Stefan Institute, Ljubljana bThe Centre of Excellence for Biosensors, Instrumentation and Process Control - COBIK, Ajdovščina, Slovenia cUniversity of Bordeaux, CNRS, INCIA, UMR 5287, Talence, France dMolecular Imaging Branch, National Institute of Mental Health, National Institute of Health, Bethesda, Maryland, USA.
Background:
Quantitative PET studies often require the cumbersome and invasive procedure of arterial cannulation to measure the input function. This study sought to minimize the number of necessary blood samples by developing a factor-analysis-based image-derived input function (IDIF) methodology for dynamic PET brain studies.
Materials And Methods:
IDIF estimation was performed as follows: (a) carotid and background regions were segmented manually on an early PET time frame; (b) blood-weighted and tissue-weighted time-activity curves (TACs) were extracted with factor analysis; (c) factor analysis results were denoised and scaled using the voxels with the highest blood signal; (d) using population data and one blood sample at 40 min, whole-blood TAC was estimated from postprocessed factor analysis results; and (e) the parent concentration was finally estimated by correcting the whole-blood curve with measured radiometabolite concentrations. The methodology was tested using data from 10 healthy individuals imaged with [(11)C](R)-rolipram. The accuracy of IDIFs was assessed against full arterial sampling by comparing the area under the curve of the input functions and by calculating the total distribution volume (VT).
Results:
The shape of the image-derived whole-blood TAC matched the reference arterial curves well, and the whole-blood area under the curves were accurately estimated (mean error 1.0±4.3%). The relative Logan-V(T) error was -4.1±6.4%. Compartmental modeling and spectral analysis gave less accurate V(T) results compared with Logan.
Conclusion:
A factor-analysis-based IDIF for [(11)C](R)-rolipram brain PET studies that relies on a single blood sample and population data can be used for accurate quantification of Logan-V(T) values.
More Related Videos
09:01A Method for Investigating Age-related Differences in the Functional Connectivity of Cognitive Control Networks Associated with Dimensional Change Card Sort Performance
Published on: May 7, 2014
08:12A Psychophysics Paradigm for the Collection and Analysis of Similarity Judgments
Published on: March 1, 2022
Related Concept Videos
Factorial Design
Association Areas of the Cortex
Prefrontal Association Area: This area is located in the frontal lobe and is involved in planning, decision-making, and moderating social behavior. It connects with primary motor areas,...
Two-Way ANOVA
The two-way ANOVA analysis initially begins by stating the null hypothesis that there is an interaction effect between the two factors of a dataset. This effect can be visualized using line segments formed by joining the...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...