Related Experiment Video
Updated: Apr 22, 2026

Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping
Published on: March 20, 2017
Coherent signal composition and global phase determination in signal multiplexed polarization sensitive optical
Abstract:
We present an analysis of the structural image information acquired with polarization sensitive optical coherence tomography (PS-OCT). In PS-OCT a total of four channels of data are acquired: two orthogonal polarization state components for each of two incident polarization states by which the sample is interrogated. Up to recently, the structural information of the sample was obtained by incoherent summation of these four channels. The four channels can be represented as a Jones matrix for each data point acquired from a sample. We show that the Signal to Noise ratio of the structural information can be improved by 2.3 dB by taking advantage of the structure of this Jones matrix, imposed by the propagation and scattering properties of the sample. We demonstrate that the Jones Matrices are all in the shape of an SU(2) matrix, which is key to understanding the coherent composition of the structural image in PS-OCT and the 2.3 dB SNR improvement. We also discuss a global phase of the Jones matrix in signal multiplexed PS-OCT.
More Related Videos
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
07:56A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
Published on: September 5, 2019
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...