Related Experiment Video
Updated: Apr 21, 2026

Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
Characterizing search, recognition, and decision in the detection of lung nodules on CT scans: elucidation with eye
Geoffrey D Rubin1, Justus E Roos, Martin Tall
1From the Duke Clinical Research Institute, Box 17969, 2400 Pratt St, Durham, NC 27715 (G.D.R., K.R.C.); Department of Radiology, Duke University School of Medicine, Durham, NC (G.D.R., J.E.R., M.T., B.H., S.B., D.M.S., L.M.H.); Department of Medical Imaging, University of Toronto, Toronto, ON, Canada (D.L.L.); and Department of Radiology, Stanford University School of Medicine, Stanford, Calif (S.N.).
Purpose:
To determine the effectiveness of radiologists' search, recognition, and acceptance of lung nodules on computed tomographic (CT) images by using eye tracking.
Materials And Methods:
This study was performed with a protocol approved by the institutional review board. All study subjects provided informed consent, and all private health information was protected in accordance with HIPAA. A remote eye tracker was used to record time-varying gaze paths while 13 radiologists interpreted 40 lung CT images with an average of 3.9 synthetic nodules (5-mm diameter) embedded randomly in the lung parenchyma. The radiologists' gaze volumes ( GV gaze volume s) were defined as the portion of the lung parenchyma within 50 pixels (approximately 3 cm) of all gaze points. The fraction of the total lung volume encompassed within the GV gaze volume s, the fraction of lung nodules encompassed within each GV gaze volume (search effectiveness), the fraction of lung nodules within the GV gaze volume detected by the reader (recognition-acceptance effectiveness), and overall sensitivity of lung nodule detection were measured.
Results:
Detected nodules were within 50 pixels of the nearest gaze point for 990 of 992 correct detections. On average, radiologists searched 26.7% of the lung parenchyma in 3 minutes and 16 seconds and encompassed between 86 and 143 of 157 nodules within their GV gaze volume s. Once encompassed within their GV gaze volume , the average sensitivity of nodule recognition and acceptance ranged from 47 of 100 nodules to 103 of 124 nodules (sensitivity, 0.47-0.82). Overall sensitivity ranged from 47 to 114 of 157 nodules (sensitivity, 0.30-0.73) and showed moderate correlation (r = 0.62, P = .02) with the fraction of lung volume searched.
Conclusion:
Relationships between reader search, recognition and acceptance, and overall lung nodule detection rate can be studied with eye tracking. Radiologists appear to actively search less than half of the lung parenchyma, with substantial interreader variation in volume searched, fraction of nodules included within the search volume, sensitivity for nodules within the search volume, and overall detection rate.
More Related Videos
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
07:26Characterizing the Relationship Between Eye Movement Parameters and Cognitive Functions in Non-demented Parkinson's Disease Patients with Eye Tracking
Published on: September 26, 2019