Characterization of an ion sensitive field effect transistor and chloride ion selective electrodes for pH

Yuichiro Takeshita1, Todd R Martz, Kenneth S Johnson

  • 1Scripps Institution of Oceanography, University of California San Diego , 9500 Gilman Drive, La Jolla, California 92093, United States.

Analytical Chemistry
|October 18, 2014
PubMed

Related Concept Videos

Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.2K
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
2.9K
Patch Clamp01:18

Patch Clamp

Many fundamental cell functions such as muscle contraction and nerve transmission rely on the electrical signals produced by the movement of positively and negatively charged ions across the cell membrane. One competent method to record current flowing across the whole cell or single ion channel is the patch-clamp technique.
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
6.0K
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
2.4K
Transport Number01:31

Transport Number

The transport number is the fraction of the total current carried by an ion in an electrolyte solution. It is defined as the ratio of the current carried by a specific ion to the total current flowing through the solution. The transport number, t, is central to understanding ionic mobility, which describes how fast an ion moves under the influence of an electric field. This link connects the physical behavior of ions in solution to the chemical processes that occur during electrochemical...
203
Ion Channels01:19

Ion Channels

The movement of ions like sodium, potassium, and calcium into and out of the cell is essential to maintain the electrochemical gradient in living cells. The ion channels—a class of membrane transport proteins—help maintain this ionic gradient for the smooth functioning of physiological activities such as maintaining cell size and volume, conducting nerve impulses, and gas and nutrient exchange.
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
68.0K