Related Experiment Video
Updated: Apr 21, 2026

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Variability and repeatability of quantitative, Fourier-domain optical coherence tomography Doppler blood flow in
Faryan Tayyari1, Firdaus Yusof2, Michal Vymyslicky1
1Retina Research Group, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.
Purpose:
The purpose of this study was to determine the within-session variability and between-session repeatability of spectral Fourier-domain optical coherence tomography (Doppler FD-OCT) Doppler retinal blood flow measurements in young and elderly subjects.
Methods:
Doppler FD-OCT blood flow was measured using the RTVue system. One eye of each of 20 healthy young (24.7 ± 2.7 years) and 16 healthy elderly (64.6 ± 5.1 years) subjects was randomly selected, and the pupil was dilated. The double circular scanning pattern of the RTVue was employed. Six Doppler FD-OCT measurements (i.e., each separate measurement comprising an upper and a lower nasal pupil scan) were acquired at each session. Measurements were repeated approximately 2 weeks later. Total retinal blood flow was calculated by summing flow from all detectable venules surrounding the optic nerve head. The coefficient of variation (COV) and coefficient of repeatability (COR) were calculated for each individual.
Results:
The individual COVs for retinal blood flow for young subjects ranged from 0.4% to 20.4% (median 7.5%) and for the elderly subjects ranged from 0.6% to 34.6% (median 9.2%). The group mean CORs for retinal blood flow for young participants were 6.4 μL/min (median 5.91 μL/min, relative to a mean effect 39.8 μL/min) and for elderly subjects were 10.5 μL/min (median 9.2 μL/min, relative to a mean effect 46.4 μL/min).
Conclusions:
Doppler FD-OCT gave consistent and repeatable blood flow measurements within retinal venules in normal subjects. Considering the individual variation in blood flow measurements, confidence limits for retinal hemodynamics need to be determined on an individual basis.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Blood Flow
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)