Related Experiment Video
Updated: Apr 21, 2026

Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Interpretation of X-ray absorption spectra of As(III) in solution using Monte Carlo simulations
Jesus Canche-Tello1, M Cristina Vargas, Jorge Hérnandez-Cobos
1Departamento de Fisica Aplicada, Cinvestav-Merida , Carretera Antigua a Progreso km. 6, Merida, Yucatán 97310, Mexico.
Abstract:
We performed X-ray absorption spectroscopy measurements on the arsenic K-edge of As(III) in solution under acidic conditions. Extended X-ray absorption fine structure (EXAFS) and X-ray near edge structure (XANES) spectra were compared with theoretical calculations which use local atomic structure configurations, either derived from density functional theory (DFT) energy minimization (EM) calculations or based on classical Monte Carlo (MC) simulations, for a As(OH)3 cluster surrounded by water molecules. The nearest arsenic-oxygen distances obtained from the fit of the XAFS spectra are consistent with the distances present in configurations derived from Monte Carlo simulations but not with those obtained from DFT-EM calculations. Calculations of XANES using either DFT-EM or the average configuration obtained from MC simulations do not reproduce the XANES spectra in the vicinity of the absorption edge. However, specific local atomic structural configurations of the As(OH)3 and water molecules, obtained from MC simulations, which show some ordering of water molecules up to 5 Å from the arsenic, reproduce qualitatively the experimental spectra. These results highlight the capability of XANES to yield information about hydration of ions in solution.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Lab
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...

