New technological and clinical trends in blood pressure theranostics: is it time to consider a spatio-temporal
Theodore G Papaioannou, Manolis Vavuranakis, Christodoulos Stefanadis
1Biomedical Engineering Unit, 1st Dept. of Cardiology, Hippokration Hospital 114 Vas Sophias ave., Athens 115 28, Greece. thepap@med.uoa.gr.
Abstract:
Blood pressure (BP) is traditionally assessed, for centuries, at the brachial artery by cuff-based sphygmomanometric techniques. Technological and methodological innovations as well as emerging new findings from clinical studies and trials now provoke a re-consideration of traditional strategies for BP management. The existing knowledge regarding the occurring changes of BP over time (temporal variability) and the evident differences of BP levels between central and peripheral arteries (spatial variability) now pilots the progress in current therapeutic and diagnostic ("theranostic") concepts and practices in hypertension. This special issue of Current Pharmaceutical Design covers current and intriguing topics regarding the technological, physiological, diagnostic, therapeutic and prognostic aspects of "spatio-temporal" assessment of BP variations. Moreover an in-depth analysis of other topics such as antihypertensive drugs metabolism and polypharmacy at the elderly are included.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...