Efficacy of High-volume Evacuator in Aerosol Reduction: Truth or Myth? A Clinical and Microbiological Study
Hitesh Desarda1, Abhijit Gurav2, Chandrakant Dharmadhikari3
1Post-graduate Student, Department of Periodontology, Tatyasaheb Kore Dental College and Research Centre, New Pargaon, Kolhapur, Maharashtra, India.
Abstract:
Background and aims. Basic periodontal treatment aims at eliminating supra- and sub-gingival plaque and establishing conditions which will allow effective self-performed plaque control. This aim is primarily achieved with sonic and ultrasonic scalers. However, generation of bacterial aerosols during these procedures is of great concern to patients, the dentist and the dental assistant. The aim of this study was to compare the reduction in aerosol with and without high-volume evacuator through a microbiological study. Materials and methods. For this clinical study a fumigated closed operatory was selected. Maxillary incisors and canines were selected as an area for scaling. Piezoelectric ultrasonic scaling was performed in the absence and in the presence of a high-volume evacuator at 12 and 20 inches from the patient's oral cavity. In both groups scaling was carried out for 10 minutes. Nutrient agar plates were exposed for a total of 20 minutes. After this procedure, nutrient agar plates were incubated in an incubator at 37°C for 24 hours. The next day the nutrient agar plates were examined for colony forming units by a single microbiologist. Results. The results showed no statistically significant differences in colony forming units (CFU) with and without the use of a high-volume evacuator either at 12 or 20 inches from the patient's oral cavity. Conclusion. It was concluded that high-volume evacuator, when used as a separate unit without any modification, is not effective in reducing aerosol counts and environmental contamination.
More Related Videos
07:28Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Inhaled Medications
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...