Related Experiment Video
Updated: Apr 21, 2026

Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
Published on: February 5, 2020
Comparison of power output during ergometer and track cycling in adolescent cyclists
Alfred Nimmerichter1, Craig A Williams
11Sport and Exercise Sciences, University of Applied Sciences, Wiener Neustadt, Austria; and 2Children's Health and Exercise Research Centre, Sport and Health Sciences, University of Exeter, Exeter, United Kingdom.
Abstract:
The aim of this study is to establish the level of agreement between test performance of young elite cyclists in a laboratory and a track field-based trial. Fourteen adolescent cyclists (age: 14.8 ± 1.1 years; (Equation is included in full-text article.): 63.5 ± 5.6 ml·min(-1)·kg(-1)) performed 3 tests of 10 seconds, 1 minute, and 3 minutes on an air-braked ergometer (Wattbike) and on a 250-m track using their own bikes mounted with mobile power meters (SRM). The agreement between the maximum and mean power output (Pmax and Pmean) measured on the Wattbike and SRM was assessed with the 95% limits of agreement (LoA). Power output was strongly correlated between Wattbike and SRM for all tests (r = 0.94-0.96; p < 0.001). However, power output was significantly higher on the Wattbike compared with track cycling during all tests. The bias and 95% LoA were 76 ± 78 W (8.8 ± 9.5%; p = 0.003, d = 0.38) for Pmax10s and 82 ± 55 W (10.9 ± 7.9%; p < 0.001, d = 0.46) for Pmean10s. During the 1- and 3-minute test, the bias and 95% LoA were 72 ± 30 W (17.9 ± 7.1%; p < 0.001, d = 0.84) and 28 ± 20 W (9.6 ± 6.1%; p < 0.001, d = 0.51), respectively. Laboratory tests, as assessed using a stationary ergometer, resulted in maximal and mean power output scores that were consistently higher than a track field-based test using a mobile ergometer. These results might be attributed to the technical ability of the riders and their experience to optimize gearing and cadence to maximize performance. Prediction of field-based testing on the track from laboratory tests should be used with caution.
More Related Videos
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Efficiency of The Carnot Cycle
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Power
Average Power