Hydrogen-deuterium exchange mass spectrometry as an emerging analytical tool for stabilization and formulation

Ranajoy Majumdar1, C Russell Middaugh, David D Weis

  • 1Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, Kansas, 66047; Macromolecule and Vaccine Stabilization Center, University of Kansas, Lawrence, Kansas, 66047.

The dynamic nature of the structure of monoclonal antibodies (mAbs) can be probed at a resolution of 5-20 residues using hydrogen-deuterium exchange mass spectrometry (H/D-MS). Recent studies using H/D-MS have shown that distinct regions of IgG1 mAbs experience significant changes in backbone dynamics in response to specific physicochemical alterations, varying solution conditions, or exposure to different environmental stresses. Tracking such changes in local dynamics may therefore serve as a key analytical tool, not only to monitor stability changes, but also to design improved, and more stable formulations of therapeutic mAbs in pharmaceutical dosage forms. This review article describes the H/D-MS method as applied to the analysis of formulations containing mAbs and summarizes recent studies monitoring changes in mAb local dynamics in response to chemical modifications, physical degradation, and presence of stabilizing and destabilizing excipients. Furthermore, the nature of the local dynamics of a highly conserved peptide segment in the CH 2 domain of IgG1 mAbs is reviewed, and the results are correlated with decreased pharmaceutical stability, supporting the identification of a common aggregation hotspot sequence in the Fc region of human IgG1 mAbs. In addition, unresolved challenges (and opportunities) in applying H/D-MS technology for stabilization and formulation development of mAbs are discussed.

Related Concept Videos

Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
3.0K
¹H NMR of Labile Protons: Deuterium (²H) Substitution00:48

¹H NMR of Labile Protons: Deuterium (²H) Substitution

This lesson illustrates the role of deuterium substitution in simplifying the NMR spectrum of compounds comprising labile protons. One method employed is the use of deuterium. Amongst the three isotopes of hydrogen, deuterium (2H) has a nucleus composed of one proton and one neutron. When the D2O solvent is added to a pure dry ethanol solution, its labile proton is substituted with deuterium.
996
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
6.2K
Hybridoma Technology01:31

Hybridoma Technology

Hybridoma technology is used for the large-scale production of monoclonal antibodies. Monoclonal antibodies bind to only a single antigenic determinant or epitope. Such antibodies are used in research, diagnostics, and disease therapy. The hybridoma technology established in 1975 by Georges Köhler and Cesar Milstein was awarded the Nobel Prize in Medicine in 1984 for revolutionizing research and therapy.
Hybridoma Selection
Commonly used fusion techniques — electroporation,...
13.0K
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
2.5K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
2.1K