Dynamic device properties of pulse contour cardiac output during transcatheter aortic valve implantation
Martin Petzoldt1, Carsten Riedel, Jan Braeunig
1Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany, m.petzoldt@uke.de.
Abstract:
This prospective single-center study aimed to determine the responsiveness and diagnostic performance of continuous cardiac output (CCO) monitors based on pulse contour analysis compared with invasive mean arterial pressure (MAP) during predefined periods of acute circulatory deterioration in patients undergoing transcatheter aortic valve implantation (TAVI). The ability of calibrated (CCO(CAL)) and self-calibrated (CCO(AUTOCAL)) pulse contour analysis to detect the hemodynamic response to 37 episodes of balloon aortic valvuloplasty enabled by rapid ventricular pacing was quantified in 13 patients undergoing TAVI. A "low" and a "high" cut-off limit were predefined as a 15 or 25 % decrease from baseline respectively. We found no significant differences between CCO(CAL) and MAP regarding mean response time [low cut-off: 8.6 (7.1-10.5) vs. 8.9 (7.3-10.8) s, p = 0.76; high cut-off: 11.4 (9.7-13.5) vs. 12.6 (10.7-14.9) s, p = 0.32] or diagnostic performance [area under the receiver operating characteristics curve (AUC): 0.99 (0.98-1.0) vs. 1.0 (0.99-1.0), p = 0.46]. But CCOCAL had a significantly higher amplitude response [95.0 (88.7-98.8) % decrease from baseline] than MAP [41.2 (30.0-52.9) %, p < 0.001]. CCOAUTOCAL had a significantly lower AUC [0.83 (0.73-0.93), p < 0.001] than MAP. Moreover, CCO(CAL) detected hemodynamic recovery significantly earlier than MAP. In conclusion, CCO(CAL) and MAP provided equivalent responsiveness and diagnostic performance to detect acute circulatory depression, whereas CCO(AUTOCAL) appeared to be less appropriate. In contrast to CCO(CAL) the amplitude response of MAP was poor. Consequently even small response amplitudes of MAP could indicate severe decreases in CO.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Aortic Regurgitation I: Introduction