Related Experiment Video
Updated: Apr 21, 2026

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Modeling the Raman spectrum of graphitic material in rock samples with fluorescence backgrounds: accuracy of fitting
Patrick J Gasda1, Ryan C Ogliore
1Hawai'i Institute of Geophysics and Planetology, University of Hawai'i, Manoa, 1680 East West Road, Honolulu, HI 96822 USA.
Abstract:
We propose a robust technique called Savitzky-Golay second-derivative (SGSD) fitting for modeling the in situ Raman spectrum of graphitic materials in rock samples such as carbonaceous chondrite meteorites. In contrast to non-derivative techniques, with assumed locally linear or nth-order polynomial fluorescence backgrounds, SGSD produces consistently good fits of spectra with variable background fluorescence of any slowly varying form, without fitting or subtracting the background. In combination with a Monte Carlo technique, SGSD calculates Raman parameters (such as peak width and intensity) with robust uncertainties. To explain why SGSD fitting is more accurate, we compare how different background subtraction techniques model the background fluorescence with the wide and overlapping peaks present in a real Raman spectrum of carbonaceous material. Then, the utility of SGSD is demonstrated with a set of real and simulated data compared to commonly used linear background techniques. Researchers may find the SGSD technique useful if their spectra contain intense background interference with unknown functional form or wide overlapping peaks, and when the uncertainty of the spectral data is not well understood.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Fluorescence Spectroscopy
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...