Related Experiment Video
Updated: Apr 21, 2026

Author Spotlight: A Single-Entry Point Endoscopic Intraventricular Approach for Third Ventriculostomy and Pineal Biopsy
Published on: June 28, 2024
Neuroendoscopic biopsy of brain lesions: accuracy and complications
Alexandre Varella Giannetti1, Alexandre Yugo Holayama Alvarenga, Thiago Oliveira Lemos de Lima
1Department of Surgery, School of Medicine, and.
Object:
The authors conducted a study to analyze the accuracy of neuroendoscopic biopsies of ventricular and periventricular lesions and record any difficulties or complications of the neuroendoscopic biopsy procedure.
Methods:
A total of 50 patients with different diseases consecutively underwent endoscopic biopsy procedures. The biopsy result was considered diagnostic if the pathologist reported any specific finding on which clinicians could base decisions about treatment or observation. The biopsy result was referred to as accurate if the results matched results of a sample obtained later or if the treatment response and disease evolution were compatible with the diagnosis. The biopsy result was considered inaccurate if results showed any relevant differences from those of the later sample or if the patient's disease did not evolve as expected. Complications were recorded and compared with those found in a literature review.
Results:
For 2 patients, the procedure had to be terminated. The biopsy diagnostic rate was 89.6%, and the accuracy rate was 86%. Complications associated with the procedure were 3 hemorrhages (6%), 2 infections (4%), and 1 death (2%); no reoperations were needed.
Conclusions:
Endoscopic biopsy seems to be an accurate procedure with acceptable morbidity and mortality rates.