Related Experiment Video
Updated: Apr 21, 2026

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Influence of different oxygenator types on changing frequency, infection incidence, and mortality in ARDS patients on
Oliver Robak1, Philipp K S Lakatos, Andja Bojic
11 Department of Internal Medicine I, Intensive Care Unit, Medical University of Vienna, Vienna - Austria.
Purpose:
Veno-venous extracorporeal membrane oxygenation (vv-ECMO) is pivotal in the treatment of patients suffering from acute respiratory distress syndrome (ARDS). Comparative data with different oxygenator models have not yet been reported. The aim of this retrospective investigation was therefore to assess whether different oxygenator types might influence changing frequency, infection incidence, and mortality in patients on vv-ECMO.
Methods:
42 patients undergoing vv-ECMO between 1998 and 2009 were identified. In 20 out of these patients, a polypropylene (PP) microporous hollow fiber membrane oxygenator, and in 22 patients a nonmicroporous polymethylpentene (PMP) diffusion membrane oxygenator was used. Infection incidence, changing frequency, and mortality were documented.
Results:
In the PMP group, an oxygenator change was necessary less often than in the PP group (p<0.001). The incidence of bacterial, viral, or fungal growth was similar in the groups, thus independent of the frequency of oxygenator change. Irrespective of the groups, the occurrence of Candida sp. tended to correlate with death (p = 0.06). In general, there was a trend towards a higher infection incidence in the subgroup with pulmonary ARDS (p = 0.07). Moreover, infection incidence was associated with a longer ICU stay (p = 0.03) and longer ECMO therapy (p = 0.03). ICU mortality was lower in the PMP group than in the PP group, although not statistically significant (p = 0.10).
Conclusions:
The PMP oxygenator membranes showed benefits with regards to changing frequency, but not infection incidence, length of ICU stay, and length of ECMO therapy. There was a trend towards a lower ICU mortality in patients with PMP oxygenators.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Transport in the Blood
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...