Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
Simultaneous N, C, S stable isotope analyses using a new purge and trap elemental analyzer and an isotope ratio mass
François Fourel1, François Martineau, Magali Seris
1Laboratoire de Géologie de Lyon "Terre, Planètes Environnement", CNRS UMR 5276, Université Claude Bernard Lyon 1, Ecole Normale Supérieure de Lyon, Campus de la Doua, F-69622, Villeurbanne, France.
Rationale:
The evolution of stable isotope applications has demonstrated the increasing need for the determination of more than one isotopic signature from the same sample. Simultaneous determinations of (13)C/(12)C and (15)N/(14)N have become a widespread technique but up to now very few fully automated systems have offered the possibility of also measuring (34)S/(32)S from the same sample aliquot. This could be critical when sample amounts are limited, but it could also represent a significant gain of analytical time or cost. The technique that we are presenting provides these multiple isotopic signatures on small sample aliquots with high precisions, especially for sulfur determinations.
Methods:
A high-precision, easy and rapid method for the simultaneous measurement of carbon ((13)C/(12)C), nitrogen ((15)N/(14)N) and sulfur ((34)S/(32)S) ratios as well as elemental concentrations was employed, using a new combination of an elemental analyzer and an isotope ratio mass spectrometer. The elemental analyzer was based on 'purge and trap' technology rather than conventional packed-gas chromatography (GC) gas separation. Emphasis was put on the efficiency of the system to reliably combust sulfur-bearing compounds of both organic and inorganic origin with high conversion yields.
Results:
High-quality measurement of (34)S/(32)S ratios was obtained using various international reference materials. A working calibrated material was also selected and characterized for all three isotopic signatures in order to fully use the capacities of the system in future work.
Conclusions:
The possibilities of such a system for the reliable measurement of S isotope ratios as well as N and C isotope ratios within the same aliquot of sample opens up new fields of investigation in many domains where multi-isotopic approaches are required.
More Related Videos
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
12:10Stable Isotopic Profiling of Intermediary Metabolic Flux in Developing and Adult Stage Caenorhabditis elegans
Published on: February 27, 2011
Related Concept Videos
Mass Spectrometry: Isotope Effect
Tandem Mass Spectrometry
Mass Analyzers: Common Types
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences