Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
[Assessment of left ventricular twist in type 2 diabetes mellitus by using two-dimensional ultrasound speckle
Pei-hua Zhu1, Jing-yuan Huang1, Meng Ye1
1Department of Ultrasonography,Zhejiang Hospital,Hangzhou 310013,China.
Objective:
To evaluate the left ventricular twist characteristics in patients with type 2 diabetes by using two-dimensional speckle tracking imaging (STI).
Methods:
Ninety-three patients with type 2 diabetes admitted in Zhejiang Hospital from May 2012 to September 2013 were enrolled. According to left ventricular ejection fraction (LVEF), patients were divided into two groups: normal left ventricular systolic function group (group A, LVEF≥0.50, n=46) and abnormal left ventricular systolic function group (group B, LVEF <0.50, n=47). Forty-six healthy subjects were selected as normal controls. STI was applied to quantitatively analyze the left ventricular twist. Correlation of the peak of left ventricular twist angle (Peaktw), aortic valve closure time twist angle (AVCtw), and mitral valve opening time twist angle (MVOtw) with LVEF, Tei index, E/A, and E/e was evaluated. Consistency check for STI was conducted to assess its stability and reliability.
Results:
The Peaktw, AVCtw, and MVOtw in group A were significantly elevated than those in normal controls (P<0.05). The Peaktw, AVCtw, and MVOtw in group B was lower than those in normal controls and group A (P<0.05). In diabetic patients, the Peaktw, AVCtw, MVOtw were positively correlated with LVEF (r=0.968, 0.966, 0.938;P<0.05) and E/A (r=0.798, 0.790, 0.788; P<0.05), and were negatively correlated with Tei index (r=-0.834, -0.811, -0.797; P<0.05) and E/e (r=-0.823, -0.805, -0.771; P<0.05). The agreement between measurers and within measurers of Peaktw was satisfactory (between measurers: R=0.957, bias=-0.1, 95% consistency limit=-2.8-2.7; within measurer: R=0.964, bias=-0.2, 95% consistency limits=-2.7-2.2).
Conclusion:
STI can be used for early recognition of abnormal changes of cardiac function in type 2 diabetic mellitus patients, with high stability and reliability.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: