Related Experiment Video
Updated: Apr 21, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Confirmation of correct central venous catheter position in the preoperative setting by echocardiographic
M Meggiolaro1, A Scatto, A Zorzi
1Division of Anaesthesiology and Intensive Care, University Hospital of Padua, Padua, Italy - meggiomarco@libero.it.
Background:
Verification of the central venous catheters (CVCs) position by chest X-ray (CXR) is usually performed in the postoperative period with the risk related to possible malposition. This prospective observational study aimed to assess the diagnostic accuracy and reproducibility of ultrasound (US) and "bubble test" to detect malpositions of CVC in the preoperative setting.
Methods:
The study included 105 patients undergoing preoperative CVC placement. A US protocol aimed at direct visualization of the CVC was completed by a single operator and two consecutive "bubble tests" were performed independently by different physicians. Two parameters were considered: complete right atrium (RA) opacization versus visualization of "no or few bubbles" and time from agitated saline injection to visualization of micro-bubbles in the RA ("push-to-bubbles" time).
Results:
CXR identified 14 (13%) CVC malpositions. Vascular US showed a sensitivity of 64% and a specificity of 100% while visualization of "no or few bubbles" at bubble test yielded a sensitivity of 50% and a specificity of 100%. "Push-to-bubbles" times were ≈9 times longer in patients with compared to those without CVC malposition (1400 [702-2160] ms versus 167 [123-228] ms, P<0.001). A cut off value of 500 ms had a sensitivity of 100% and a specificity of 99% for CVC malposition with an inter-observer agreement of 99% (kappa 0.96, P<0.001).
Conclusion:
CVC malposition was observed in a sizeable proportion of patients undergoing preoperative central venous cannulation. Measurement of "push-to-bubbles" time is a fast, accurate and highly reproducible tool for verifying the correct CVC position.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization

