Stopped extracorporeal circulation without alarm call due to voltage regulator failure
Masato Ichikawa1, Ichiro Takeuchi, Takao Konishi
1Department of Clinical Engineering, Mikamikai Yasu Hospital, Shiga, Japan.
Blood Purification
|November 8, 2014
Abstract
No abstract available in PubMed .
Related Concept Videos
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
361
Hemoperfusion and hemofiltration are critical techniques in medical treatments to eliminate accumulated drugs, metabolites, and electrolytes from the bloodstream. These methods are particularly vital in cases of accidental poisoning and drug overdose.Hemoperfusion involves passing blood through an adsorbent material to remove unwanted substances. The main adsorbents used in hemoperfusion include activated charcoal and Amberlite resins. Activated charcoal can adsorb both polar and nonpolar...
361
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
388
Continuous Renal Replacement Therapy (CRRT) is an essential intervention for patients experiencing severe kidney dysfunction. This therapy offers a continuous mechanism for removing fluids and toxins from the bloodstream, leveraging the patient’s blood pressure to facilitate filtration through a specialized filter. This method contrasts with intermittent dialysis, providing a gentler and more consistent removal of waste products and excess fluid, which is particularly beneficial in...
388
Voltage Doubler Circuit
2.3K
A voltage doubler circuit integrates two main components: a clamping section and a rectifier section. The clamping section consists of a capacitor (C1) and a diode (D1), whereas the rectifier section is equipped with another diode (D2) and capacitor (C2). This circuit produces an output voltage with twice the amplitude of the sinusoidal input voltage.
2.3K
Bridge rectifier
2.1K
The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
2.1K
Node Analysis for AC Circuits
812
Consider an angioplasty system featuring a catheter equipped with a turbine, a critical tool for removing plaque deposits from coronary arteries. This intricate medical device operates using a circuit model reminiscent of a dual-node RLC circuit powered by a current-controlled voltage source.
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
812
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
1.0K
Patients with end-stage renal disease (ESRD) or those experiencing drug overdose often require extracorporeal methods to eliminate accumulated drugs and metabolites. Hemoperfusion, hemofiltration, and dialysis are the primary techniques to rapidly remove harmful substances without disrupting the patient's fluid and electrolyte balance. For those with compromised renal function, dosage adjustments of concurrent medications may be necessary during extracorporeal drug removal.Dialysis is a process...
1.0K