Related Experiment Video
Updated: Apr 21, 2026

Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
Pocket-sized ultrasound as an aid to physical diagnosis for internal medicine residents: a randomized trial
Jason C Ojeda1, James A Colbert, Xinyi Lin
1Department of Medicine, Jefferson University, Philadelphia, PA, USA.
Background:
Proficiency and self-confidence in the physical examination is poor among internal medicine residents and interest in ultrasound technology has expanded.
Objective:
We aimed to determine whether a pocket-sized ultrasound improves the diagnostic accuracy and confidence of residents after a 3-h training session and 1 month of independent practice.
Design:
This was a randomized parallel group controlled trial.
Participants:
Forty internal medicine residents in a single program at an academic medical center participated in the study.
Intervention:
Three hours of training on use of pocket-sized ultrasound was followed by 1 month of independent practice.
Main Measures:
The primary outcome was a comparison of the diagnostic accuracy of a physical exam alone versus a physical examination augmented with a pocket-sized ultrasound. Other outcomes included confidence in exam findings and a survey of attitudes towards the physical exam and the role of ultrasound.
Key Results:
Residents in the intervention group using a pocket-sized ultrasound correctly identified an average of 7.6 of the 17 abnormal findings (accuracy rate of 44.9 %). Those in the control group correctly identified an average of 6.4 abnormal findings (accuracy rate of 37.6 %, p = 0.11). Residents in the intervention group identified on average 15.9 findings as abnormal when no abnormality existed (false positive rate of 16.8 %). Those in the control group incorrectly identified an average of 15.5 positive findings (false positive rate of 16.3 %). There was no difference between groups regarding self-assessed confidence in physical examination. Residents in the intervention group identified 6.1 of 13 abnormal cardiac findings versus the control group's 4.5 of 13, an accuracy rate of 47.0 % versus 34.6 % (p = 0.023).
Conclusions:
The diagnostic ability of internal medicine residents did not significantly improve with use of a pocket-sized ultrasound device after a 3-h training session and 1 month of independent practice.
Trial Registration:
clinicaltrials.gov: number NCT01948076; URL http://clinicaltrials.gov/ct2/show/study/NCT01948076?term=ultrasound+physical+exam&rank=2.
More Related Videos
07:12Author Spotlight: Using Point-of-Care Ultrasound for Comprehensive Evaluation of the Abdominal Aorta
Published on: September 8, 2023
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography