Related Experiment Video
Updated: Apr 21, 2026

Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction
Published on: February 15, 2018
Concentration-related response potentiometric titrations to study the interaction of small molecules with large
Ezat Hamidi-Asl1, Devin Daems, Karolien De Wael
1AXES Research Group and ‡Chromatographic Organic Trace Analysis, Department of Chemistry, University of Antwerp , Groenenborgerlaan 171, 2020 Antwerp, Belgium.
Abstract:
In the present paper, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small-molecule interactions is reported. This approach is fast, sensitive, reproducible, and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small-molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed into a concentration-related signal over the entire concentration interval, also at low concentrations, where the millivolt (y-axis) versus log canalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anticocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis(4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using surface plasmon resonance. The potentiometric titration approach called "concentration-related response potentiometry" is used to study molecular interaction for seven macromolecular target molecules and four small-molecule ligands.
More Related Videos
10:41Capturing the Interaction Kinetics of an Ion Channel Protein with Small Molecules by the Bio-layer Interferometry Assay
Published on: March 7, 2018
10:49Identification of Small Molecule-binding Proteins in a Native Cellular Environment by Live-cell Photoaffinity Labeling
Published on: September 20, 2016
Related Concept Videos
Potentiometric Titration: Overview
Complexometric Titration: Ligands
Potentiometry: Membrane Electrodes
Potentiometry: Overview
Complexometric Titration: Overview
Conductometric Titrations: Strong Acid-Base and Weak Acid-Base Titrations