Enhanced depth imaging spectral domain optical coherence tomography in syphilitic chorioretinitis

Emil Anthony T Say1, J Niklas Ulrich

  • 1Kittner Eye Center, Department of Ophthalmology, University of North Carolina, Chapel Hill, North Carolina.

Abstract

Related Concept Videos

Diabetic Retinopathy01:27

Diabetic Retinopathy

DefinitionDiabetic retinopathy is a microvascular complication of diabetes affecting the retinal blood vessels.Risk FactorsDiabetic retinopathy is present in almost all individuals with type 1 diabetes and more than 60% of those with type 2 diabetes after two decades of disease.The risk increases with poor glycemic control, hypertension, dyslipidemia, smoking, pregnancy, and puberty.Although cataracts and glaucoma are also more frequent in people with diabetes, retinopathy remains the leading...
11
Open Angle Glaucoma: Treatment01:27

Open Angle Glaucoma: Treatment

In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
1.1K
Angle Closure Glaucoma: Treatment01:28

Angle Closure Glaucoma: Treatment

Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.7K
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
15.4K