Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

SAGES-AHPBA 2025 guideline for the surgical management of bile duct injury following cholecystectomy.

Surgical endoscopyĀ·2025
Same author

SAGES 2025 guidelines for fluorescence image-guided gastrointestinal surgery using indocyanine green.

Surgical endoscopyĀ·2025
Same author

SAGES 2025 systematic review and meta-analysis for fluorescence image-guided gastrointestinal surgery using indocyanine green.

Surgical endoscopyĀ·2025
Same author

Predicting planned ventral hernia in trauma patients: The role of end-organ dysfunction versus fluid resuscitation.

American journal of surgeryĀ·2025
Same author

Correction: SAGES guidelines for the use of intraoperative imaging of the common bile duct.

Surgical endoscopyĀ·2025
Same author

SAGES guidelines for the use of intraoperative imaging of the common bile duct.

Surgical endoscopyĀ·2025

Related Experiment Video

Updated: Apr 21, 2026

Robotic Taj Mahal Hepatectomy for Hilar Cholangiocarcinoma
09:19

Robotic Taj Mahal Hepatectomy for Hilar Cholangiocarcinoma

Published on: July 14, 2022

4.7K

Single-site robotic cholecystectomy.

Subhashini Ayloo1, Nabajit Choudhury1

  • 1Division of General, Minimally Invasive and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA.

JSLS : Journal of the Society of Laparoendoscopic Surgeons
|November 14, 2014
PubMed
Summary

Single-site robotic cholecystectomy is a safe and feasible procedure for gallbladder removal, demonstrating minimal complications and a short learning curve for surgeons transitioning from traditional methods.

Keywords:
Robotic cholecystectomySingle site

More Related Videos

Robotic Left Hepatectomy using Indocyanine Green Fluorescence Imaging for an Intrahepatic Complex Biliary Cyst
11:03

Robotic Left Hepatectomy using Indocyanine Green Fluorescence Imaging for an Intrahepatic Complex Biliary Cyst

Published on: June 24, 2022

6.5K
Robotic Central Pancreatectomy with Roux-en-Y Pancreaticojejunostomy
10:34

Robotic Central Pancreatectomy with Roux-en-Y Pancreaticojejunostomy

Published on: November 20, 2021

6.3K

Related Experiment Videos

Last Updated: Apr 21, 2026

Robotic Taj Mahal Hepatectomy for Hilar Cholangiocarcinoma
09:19

Robotic Taj Mahal Hepatectomy for Hilar Cholangiocarcinoma

Published on: July 14, 2022

4.7K
Robotic Left Hepatectomy using Indocyanine Green Fluorescence Imaging for an Intrahepatic Complex Biliary Cyst
11:03

Robotic Left Hepatectomy using Indocyanine Green Fluorescence Imaging for an Intrahepatic Complex Biliary Cyst

Published on: June 24, 2022

6.5K
Robotic Central Pancreatectomy with Roux-en-Y Pancreaticojejunostomy
10:34

Robotic Central Pancreatectomy with Roux-en-Y Pancreaticojejunostomy

Published on: November 20, 2021

6.3K

Area of Science:

  • Minimally Invasive Surgery
  • Surgical Robotics
  • Gastrointestinal Surgery

Background:

  • Laparoscopic single-incision surgery offers aesthetic benefits but presents technical challenges.
  • A single-site robotic platform aims to overcome these laparoscopic limitations.
  • Limited literature exists on single-site robotic surgery outcomes.

Purpose of the Study:

  • To analyze surgeon experience with single-site robotic cholecystectomy.
  • To evaluate the safety and short-term outcomes of this robotic approach.
  • To assess the feasibility of robotic single-site cholecystectomy.

Main Methods:

  • Retrospective review of 31 patients undergoing single-site robotic cholecystectomy (Feb 2012 - Feb 2013).
  • Analysis of operative time, port insertion, docking, console time, blood loss, and closure.
  • Evaluation of postoperative outcomes including wound infection, bile leak, and injuries.

Main Results:

  • 31 patients completed the procedure with no conversions to open or multiport surgery.
  • No major complications such as bile duct or hepatic artery injury, bile leak, reoperations, or mortality were observed.
  • One case of superficial wound infection was reported.

Conclusions:

  • Single-site robotic cholecystectomy is a feasible and safe surgical option.
  • The transition from multiport to single-port robotic surgery involves a minimal learning curve.
  • Robotic assistance enhances the safety and efficacy of single-site cholecystectomy.