Related Experiment Video
Updated: Apr 20, 2026

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Astigmatic equivalence of 2.2-mm and 1.8-mm superior clear corneal cataract incision
Jean-Luc Febbraro1, Li Wang, Edmondo Borasio
1Rothschild Foundation, 25 rue Manin, 75019, Paris, France, jlfebbraro@fo-rothschild.fr.
Purpose:
To evaluate the astigmatic effects of 2.2-mm and 1.8-mm cataract incisions.
Methods:
A randomized prospective study of 190 eyes of 151 patients undergoing superior clear corneal incision (SCCI) was divided into three groups: 61 eyes with a control 3.2-mm SCCI; 66 eyes with a 2.2-mm SCCI; and 63 eyes with a 1.8-mm SCCI. The corneal astigmatism was measured with an autokeratometer preoperatively and 1 month after surgery. The with-the-wound (WTW), against the-wound (ATW), and WTW-ATW changes were calculated using the Holladay-Cravy-Koch formula.
Results:
The WTW, ATW, and WTW-ATW changes were significantly higher for the control 3.2-mm SCCI than for the 2.2- and 1.8-mm SCCI (all p < 0.001), and no difference was found between the 2.2- and 1.8-mm SCCI incision groups.
Conclusion:
In our study, the astigmatic effects were the same for the 2.2 mm and 1.8 mm incisions and as expected, were significantly lower than the control 3.2 mm incision group.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
05:19Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery
Published on: December 1, 2023