Depth extension and sidelobe suppression in optical coherence tomography using pupil filters
Abstract:
We demonstrate a new focus engineering scheme to achieve both extended depth of focus (DOF) and sidelobe suppression in spectral-domain optical coherence tomography (SD-OCT) system. Each of the illumination pupil function and the detection pupil function is modulated using an annular pupil filter implemented by center obscuration. The two pupil filters are arranged in a dark-field configuration such that the first sidelobe of the illumination point-spread function (PSF) matches the first minimum of the detection PSF in the lateral focal plane. We tested the feasibility of the proposed scheme numerically, and then constructed a dark-field OCT (DF-OCT) system to further verify its effectiveness experimentally. Simulation results show that a DOF gain of 4.2 can be achieved compared with a full aperture OCT (FA-OCT) system, with a suppression ratio of 2.9 dB for the first sidelobe compared with an annular-aperture bright-field OCT (BF-OCT) system. Experimental results show that the constructed DF-OCT extends the DOF by three-fold compared with the constructed FA-OCT, and suppresses the first sidelobe by 3.1 dB compared with the BF-OCT. The penalty for the extended DOF is an ~11.6 dB drop in sensitivity compared with the FA-OCT system.
More Related Videos
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
08:50Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
Published on: February 9, 2019
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...