Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

14.9K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.9K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

3.1K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
3.1K
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

15.4K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
15.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An ontology-based description of nano computed tomography measurements in electronic laboratory notebooks.

Scientific data·2026
Same author

Other science opportunities at the FCC-ee.

European physical journal plus·2026
Same author

Single exposure X-ray nano-tomography in the near-field Fresnel regime with multilayer Laue lenses.

Optics express·2025
Same author

Dedicated anticoagulation management protocols in fragility femoral fracture care - a source of significant variance and limited effectiveness in improving time to surgery: The hip and femoral fracture anticoagulation surgical timing evaluation (HASTE) study.

Injury·2024
Same author

Towards virtual histology with X-ray grating interferometry.

Scientific reports·2023
Same author

In situ observation of the percolation threshold in multiphase magma analogues.

Bulletin of volcanology·2020

Related Experiment Video

Updated: Apr 20, 2026

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.9K

Simple merging technique for improving resolution in qualitative single image phase contrast tomography.

S Irvine, R Mokso, P Modregger

    Optics Express
    |November 18, 2014
    PubMed
    Summary

    This study introduces a new method to improve image quality in a type of x-ray imaging called phase contrast tomography. Traditional methods can reduce the sharpness of images, especially when used with complex samples. The researchers developed a technique that combines two types of images—one with high resolution and one with better contrast. Using a mathematical approach called Fourier analysis, the method preserves both contrast and detail. The technique is simple to use and works well with existing imaging workflows. It is especially useful for samples with multiple materials or when using white beam radiation. The results show that the merged images are clearer and more detailed than either input alone. The researchers believe this method could be a valuable tool for improving imaging quality in various scientific applications.

    Keywords:
    phase contrast tomographyimage mergingx-ray imagingtransport-of-intensity algorithm

    Frequently Asked Questions

    More Related Videos

    3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
    07:01

    3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography

    Published on: October 24, 2019

    10.4K
    Three-Dimensional Imaging of Tumor-Bearing Tissue Using the Iterative Bleaching Extends Multiplexity Approach
    07:16

    Three-Dimensional Imaging of Tumor-Bearing Tissue Using the Iterative Bleaching Extends Multiplexity Approach

    Published on: April 25, 2025

    946

    Related Experiment Videos

    Last Updated: Apr 20, 2026

    Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
    06:25

    Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

    Published on: February 12, 2014

    8.9K
    3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
    07:01

    3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography

    Published on: October 24, 2019

    10.4K
    Three-Dimensional Imaging of Tumor-Bearing Tissue Using the Iterative Bleaching Extends Multiplexity Approach
    07:16

    Three-Dimensional Imaging of Tumor-Bearing Tissue Using the Iterative Bleaching Extends Multiplexity Approach

    Published on: April 25, 2025

    946

    Area of Science:

    • X-ray imaging and tomography
    • Image processing in materials science
    • Phase contrast imaging

    Background:

    Single-image phase contrast tomography is widely used for visualizing materials that are difficult to see using traditional x-ray imaging. This method is especially useful for dynamic samples or when ease of use is important. It relies on algorithms like transport-of-intensity (TIE) to retrieve phase information from a single image. TIE works well for binary samples and monochromatic x-rays, producing accurate quantitative phase maps. However, when applied to mixed material samples or white beam radiation, TIE still provides useful qualitative reconstructions but with reduced spatial resolution. This loss is due to TIE's behavior as a low-pass filter, which smooths out high-frequency details. Current methods do not fully address this limitation. This gap motivated the development of new approaches that preserve contrast while maintaining resolution.

    Purpose Of The Study:

    The purpose of this study was to address the spatial resolution loss in single-image phase contrast tomography caused by the low-pass filtering behavior of TIE-based algorithms. The goal was to develop a method that retains high-frequency information while improving contrast in phase reconstructions. The researchers aimed to create a technique that is simple to implement and compatible with existing reconstruction workflows. They focused on merging different types of reconstructed images to achieve this goal. The study sought to demonstrate that merging raw phase contrast images with those from phase retrieval could enhance visual quality without sacrificing resolution. The researchers also aimed to ensure the method was tunable and required minimal parameters. Their objective was to provide a practical solution for users working with mixed material samples or white beam radiation.

    Main Methods:

    The researchers proposed a merging technique based on Fourier analysis to combine two sets of reconstructed images. One set came from raw phase contrast images, and the other from images processed using the TIE algorithm. The method used a few adjustable parameters to control how the images were merged. The approach involved decomposing the images into frequency components using Fourier transforms. High-frequency details from the raw images were preserved, while the contrast improvements from the TIE images were retained. The merging process was designed to be highly compatible with standard reconstruction procedures. The technique was tested on both simulated and real-world samples to evaluate its performance. The researchers ensured the method was easy to implement and did not require complex computational resources.

    Main Results:

    The merging technique successfully improved the contrast of tomographic reconstructions without losing high-frequency spatial details. The method preserved the sharp edges and fine structures typically lost in TIE-based reconstructions. The researchers demonstrated that the merged images showed better visual quality than either input alone. The technique was effective for both simulated and real-world samples. The method's parameters were easily adjustable, allowing users to fine-tune the results. The approach maintained compatibility with existing reconstruction workflows. The results showed that the merged images retained both the contrast benefits of TIE and the resolution of raw images. The researchers concluded that the method is a practical solution for improving image quality in phase contrast tomography.

    Conclusions:

    The researchers concluded that the proposed merging technique effectively addresses the resolution loss associated with TIE-based phase retrieval. The method preserves high-frequency details while enhancing contrast in tomographic reconstructions. The technique is simple to implement and compatible with current imaging workflows. The results suggest that the method is suitable for a wide range of samples, including mixed materials and those imaged with white beam radiation. The researchers emphasized that the method's tunable parameters allow for customization based on specific imaging needs. They noted that the approach does not require complex computational resources. The study highlights the potential of the technique to improve image quality in phase contrast tomography. The authors suggest that this method could be a valuable addition to existing imaging protocols.

    The merging technique improves image contrast without losing high-frequency spatial resolution in phase contrast tomography.

    The method uses Fourier transforms to merge raw phase contrast images with those processed using the TIE algorithm.

    The TIE algorithm smooths out high-frequency details, which results in a loss of spatial resolution in reconstructed images.

    Fourier transforms decompose images into frequency components, allowing selective merging of high- and low-frequency details.

    Yes, the technique is effective for mixed material samples and works well with white beam radiation.

    The authors suggest the method is a practical solution for improving image quality in phase contrast tomography.