Related Experiment Video
Updated: Apr 20, 2026

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Endothelial shear stress estimation in the human carotid artery based on Womersley versus Poiseuille flow
Janina C V Schwarz1, Raphaël Duivenvoorden, Aart J Nederveen
1Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Abstract:
Endothelial shear stress (ESS) dynamics are a major determinant of atherosclerosis development. The frequently used Poiseuille method to estimate ESS dynamics has important limitations. Therefore, we investigated whether Womersley flow may provide a better alternative for estimation of ESS while requiring equally simple hemodynamic parameters. Common carotid blood flow, centerline velocity, lumen diameter and mean wall thickness (MWT) were measured with 3T-MRI in 45 subjects at three different occasions. Mean ESS and two measures of pulsatility [shear pulsatility index (SPI) and oscillatory shear index (OSI)] were estimated based on Poiseuille and Womersley flow and compared to the more complex velocity gradient modelling method. The association between ESS and MWT was tested with multiple linear regression analysis; interscan reproducibility was assessed using intraclass correlation coefficients (ICC). Mean ESS and pulsatility indices based on Womersley flow (ESSwq β = -0.18, P = 0.04; SPIwq β = 0.24, P = 0.02; OSIwq β = 0.18, P = 0.045), showed equally good correlations with carotid MWT as the velocity gradient method (ESSvg β = -0.23, P = 0.01; SPIvg β = 0.21, P = 0.02; OSIvg β = 0.07, P = 0.47). This in contrast to the Poiseuille flow method that only showed a good correlation for mean ESS (ESSpq β = -0.18, P = 0.04; SPIpq β = 0.14, P = 0.14; OSIpq β = 0.04, P = 0.69). Womersley and Poiseuille methods had high intraclass correlation coefficients indicating good interscan reproducibility (both ICC = 0.84, 95% confidence interval 0.75-0.90). Estimation of ESS dynamics based on Womersley flow modelling is superior to Poiseuille flow modelling and has good interscan reproducibility.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
08:50Gene Expression Analysis of Endothelial Cells Exposed to Shear Stress Using Multiple Parallel-plate Flow Chambers
Published on: October 21, 2018
Related Concept Videos
Applications of Integration to Find Blood Flow
Poiseuille's Law and Reynolds Number