Excessive variations in the plethysmographic waveform during spontaneous ventilation: an important sign of upper
1From the Department of Anesthesiology and Critical Care, Sheba Medical Center, Tel Aviv University, Tel Aviv, Israel.
Abstract:
The respiratory variations in the plethysmographic (PLET) waveform of the pulse oximeter during mechanical ventilation can be automatically quantified as the PLET variation index (PVI(®)). Like other dynamic variables, the PVI may provide useful information about fluid responsiveness but only when the patient is receiving fully controlled mechanical ventilation with no spontaneous breathing activity. However, a growing number of monitors that automatically measure and display the values of the PVI and other dynamic variables are being introduced into clinical practice. Using these monitors in spontaneously breathing patients may cause inadequately trained personnel to make erroneous decisions or may eventually lead to a total disregard of dynamic parameters altogether. The aim of this study is to call attention to the fact that excessive variations in the PVI during spontaneous ventilation, termed sPVI, should not be regarded as artifactual since they may be an early important sign of upper airway obstruction (UAO). Among the monitor screen shots that were stored for educational purposes, I have identified 4 screen shots of patients who were clinically diagnosed as having significant UAO. In all instances, UAO was associated with prominent variations in the PLET waveform. These variations were calculated as the difference between the maximal and minimal amplitudes of the PLET signal divided by either the maximal amplitude (sPVI) or by the mean of the 2 values (ΔPOP). The ranges of the measured ΔPOP and sPVI values during UAO were 28% to 42% and 25% to 39%, respectively. These values are 2 to 3 times higher than the range of 9.5% to 15% that was repeatedly found as the best threshold for the identification of fluid responsiveness in mechanically ventilated patients. In 2 of these cases, simultaneously measured values of the pulse pressure variation were high as well (19% and 34%), while the calculated pulsus paradoxus was 28 and 40 mm Hg. In 2 cases, the analog signals of impedance plethysmography and capnography persisted, despite the presence of clinically significant UAO. It is, therefore, suggested that monitoring the sPVI may be of great clinical importance in spontaneously breathing patients who are susceptible to develop UAO.
More Related Videos
09:13Method to Obtain Pattern of Breathing in Senescent Mice through Unrestrained Barometric Plethysmography
Published on: April 28, 2020
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Related Concept Videos
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities I
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...