The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Computed tomography in evaluation of revision hip arthroplasty outcomes
Andrzej Kochman1, Monika Morawska-Kochman2, Maciej Guziński2
1Trauma and Orthopaedic Department, Hospital of the Ministry of Internal Affairs in Wrocław, Poland.
Abstract:
Background. This study aimed to assess contact between Recon Shell reinforcement cages used in revision hip arthroplasty and the bony base. Radiographic examinations were performed with the use of multi-energy computed tomography. Material and methods. We tentatively assess the fixation of Burch-Schneider reinforcement cages (Recon Shell made by Aesculap company) implanted in 10 patients, using two methods of evaluation. An analysis of dual energy CT scans enabled us to assess contact between the reinforcement cages and the bony base. Results. The two methods of evaluation produced different results. The evaluation method based on the division of the acetabular component into a weight-bearing zone and a non-weight-bearing zone (accounting for screw fixation) showed lack of support in the weight-bearing zone in 6 out of 10 cases and direct contact with the implant bed in only one case. The assessment of contact at anchorage holes of reinforcement cages fixed at primary procedures revealed no such support in only one case and the presence of direct contact in 5 cases. There was no correlation between the radiological outcomes and clinical results based on the Harris Hip Score. Conclusions. 1. Multi-energy computed tomography (MARS) is useful in evaluating results of revision hip allo-plasty. 2. The introduction of new imaging techniques for the evaluation of revision procedures demonstrates a need for new, unified methods of outcome assessment adjusted to the characteristics of a particular procedure.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
06:28Anterior Cruciate Ligament Transection and Synovial Fluid Lavage in a Rodent Model to Study Joint Inflammation and Posttraumatic Osteoarthritis
Published on: September 2, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography