[Evaluation of dose output according to the objects using organ-based tube-current modulation in thoracic computed
Haruka Nunome1, Kousuke Matsubara, Tadanori Takata
1Department of Radiological Technology, Kanazawa University Hospital.
Abstract:
The purpose of this study was to evaluate the dose output according to the object using organ-based tube-current modulation in thoracic CT. The output doses with elliptical and circular shaped phantoms were measured using an ionizing CT chamber. The image noise was quantitatively measured in images obtained from the elliptical phantom. Although total dose outputs with and without the modulation were almost the same, dose outputs at a frontal angle of 120° decreased and those at another angle of 240° increased with the modulation. When the same-shaped phantoms were used, the differences in variation of dose outputs due to the difference in phantom size were small and those due to the difference in the percentage ratio of long- to short-axis diameter of the cross-section were large. There was no significant difference in the amount of noise with and without the dose modulation except for the case of overdose to the small phantom. Therefore, organ-based tube current modulation does not change the total dose output and it maintains the amount of noise by controlling the dose output for each projection angle. Additionally, this dose control is independent of the object size.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...