Respiratory sinus arrhythmia as a surrogate measure of respiratory frequency: validity and robustness to activity in rats
Related Experiment Video
Updated: Apr 20, 2026

Transesophageal Atrial Burst Pacing for Atrial Fibrillation Induction in Rats
Published on: February 14, 2022
Charly Brouillard1, Pascal Carrive2, Thomas Similowski3
1CR-ICM, UPMC/INSERM, UMR-S 975, CNRS UMR 7225, Faculté de Médecine UPMC, Site Pitie-Salpêtrière, Paris, France;
Abstract:
Recording of breathing frequency is a basic requirement for respiratory physiology. Usual techniques are invasive and constraining. Respiratory sinus arrhythmia (RSA) has recently been demonstrated to be a simple way to obtain respiration frequency at rest. In this study, we investigated whether this correlation is also observed during activity. We first compared RSA to the respiration frequency obtained in anesthetized rats using a pneumotachograph connected to the trachea (TRF). Data analyses using Passing and Bablok regression confirmed the absence of bias and proportional differences. Accordingly, the Bland-Altman plot did not show any significant differences in data sets. In a second experiment, we compared RSA to the respiration frequency obtained in freely moving rats using a subpleurally inserted telemetric catheter (PRF). Comparisons between RSA and PRF revealed no significant difference in determination of respiratory rate with the two methods, although the bias and confidence interval were greater when activity increased. This was, however, not the case during short episodes of sniffing-like tachypnea, during which no matching RSA peaks were observed. In conclusion, RSA frequency reflected regular respiration frequency independently of the level of activity and appears to be a good surrogate to usual techniques.
More Related Videos
05:28Electrophysiology on Isolated Brainstem-spinal Cord Preparations from Newborn Rodents Allows Neural Respiratory Network Output Recording
Published on: November 19, 2015
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Volumes and Capacities I
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Factors Affecting Respiration
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...