A perimetric test procedure that uses structural information
Shonraj Ballae Ganeshrao1, Allison M McKendrick, Jonathan Denniss
1*MPhil †PhD Computing and Information Systems (SBG, JD, AT), and Optometry and Vision Sciences (AMM, JD), the University of Melbourne, Melbourne, Victoria, Australia.
Purpose:
To develop a perimetric test strategy, Structure Estimation of Minimum Uncertainty (SEMU), that uses structural information to drive stimulus choices.
Methods:
Structure Estimation of Minimum Uncertainty uses retinal nerve fiber layer (RNFL) thickness data as measured by optical coherence tomography to predict perimetric sensitivity. This prediction is used to set suprathreshold levels that then alter a prior probability distribution of the final test output. Using computer simulation, we studied SEMU's performance under three different patient error response conditions: No Error, Typical False Positive errors, and Extremely Unreliable patients. In experiment 1, SEMU was compared with an existing suprathreshold cum thresholding combination test procedure, Estimation of Minimum Uncertainty (EMU), on single visual field locations. We used these results to finalize SEMU parameters. In experiment 2, SEMU was compared with full threshold (FT) on 163 glaucomatous visual fields.
Results:
On individual locations, SEMU has similar accuracy to EMU, but is, on average, one presentation faster than EMU. For the typical false-positive error condition, SEMU has significantly lower error compared with FT (SEMU average 0.33 dB lower; p < 0.001) and the 90% measured sensitivity range for SEMU is also smaller than that for FT. For unreliable patients, however, FT has lower mean and SD of error. Structure Estimation of Minimum Uncertainty makes significantly fewer presentations than FT (1.08 presentation on average fewer in a typical false-positive condition; p < 0.001). Assuming that a location in the field is marked abnormal if it falls below the 5th percentile of normal, SEMU has a false-positive rate of less than 10% for all error conditions compared with FT's rate of 20% or more.
Conclusions:
On average, simulations show that using RNFL information to guide stimulus placement in a perimetric test procedure maintains accuracy, improves precision, and decreases test duration for patients with less than 15% false-positive rates.
Related Concept Videos
Moment-Area Theorems
The theorem is divided into two parts. The first part connects the angle between tangents at any two points on the beam's elastic curve to the area under a curve derived by...
Structural Properties and Dimensions of Lumber
The strength characteristics of...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Beams with Symmetric Loadings
The M/EI...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...