Straight versus modiolar hugging electrodes: does one perform better than the other?
Jayesh Doshi1, Peter Johnson, Deborah Mawman
1*Department of Otolaryngology, and †Manchester Auditory Implant Centre, Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre; ‡Respiratory and Allergy Centre, Institute of Inflammation and Repair, and §Institute of Cancer Services, University of Manchester, Manchester, United Kingdom.
This study found no significant difference in speech perception outcomes between the CI422 and Contour cochlear implants at 3 and 9 months post-implantation. Both devices effectively improved patient speech perception after surgery.
Area of Science:
- Audiology
- Neurosurgery
- Biomedical Engineering
Background:
- Cochlear implants (CI) are vital for restoring hearing in individuals with severe to profound sensorineural hearing loss.
- The selection of an appropriate CI electrode is crucial for optimizing post-operative speech perception.
- The CI422 and Contour devices represent different technological approaches to cochlear implantation.
Purpose of the Study:
- To compare speech perception outcomes in adult patients receiving either the CI422 or Contour cochlear implant.
- To identify any statistically significant differences in auditory performance between the two implant types.
Main Methods:
- A retrospective case review was conducted at a tertiary referral center.
- Thirty-two adult patients who underwent cochlear implantation were included.
- Speech perception was assessed using Bamford-Kowal-Bench (BKB) scores at 3 and 9 months post-activation.
Main Results:
- At 3 months, mean BKB scores were 86.0% (quiet) and 55.1% (noise) for CI422, versus 86.0% (quiet) and 62.3% (noise) for Contour.
- At 9 months, mean BKB scores were 85.9% (quiet) and 67.1% (noise) for CI422, versus 90.1% (quiet) and 77.6% (noise) for Contour.
- No statistically significant differences (p > 0.05) in speech perception were observed between the CI422 and Contour groups at either time point.
Conclusions:
- Both CI422 and Contour cochlear implants significantly enhance post-operative speech perception.
- The study indicates no discernible difference in speech perception outcomes between the CI422 and Contour electrode devices.
- These findings support the efficacy of both implant types in improving auditory function.
Related Concept Videos
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Standard Electrode Potentials
Potentiometry: Membrane Electrodes
Processes at Electrodes
Voltammetric Techniques: Linear-Scan (E vs Time)