1Department of Anesthesiology and Intensive Care Medicine, University Medical Center Freiburg, Hugstetter Straße 55, Freiburg D-79106, Germany steffen.wirth@uniklinik-freiburg.de.
Background:
Lung-protective mechanical ventilation during general surgery including the application of PEEP can reduce postoperative pulmonary complications. In a prospective clinical observation study, we evaluated volume-dependent respiratory system compliance in adult patients undergoing ear-nose-throat surgery with ventilation settings chosen empirically by the attending anaesthetist.
Methods:
In 40 patients, we measured the respiratory variables during intraoperative mechanical ventilation. All measurements were subdivided into 5 min intervals. Dynamic compliance (CRS) and the intratidal volume-dependent CRS curve was calculated for each interval and classified into one of the six specific compliance profiles indicating intratidal recruitment/derecruitment, overdistension or all. We retrospectively compared the occurrences of the respective compliance profiles at PEEP levels of 5 cm H2O and at higher levels.
Results:
The attending anaesthetists set the PEEP level initially to 5 cm H2O in 29 patients (83%), to 7 cm H2O in 5 patients (14%), and to 8 cm H2O in 2 patients (6%). Across all measurements the mean CRS was 61 (11) ml cm H2O(-1) (40-86 ml cm H2O(-1)) and decreased continuously during the procedure. At PEEP of 5 cm H2O the compliance profile indicating strong intratidal recruitment/derecruitment occurred more often (18.6%) compared with higher PEEP levels (5.5%, P<0.01). Overdistension was practically never observed.
Conclusions:
In most patients, a PEEP of 5 cm H2O during intraoperative mechanical ventilation is too low to prevent intratidal recruitment/derecruitment. The analysis of the intratidal compliance profile provides the rationale to individually titrate a PEEP level that stabilizes the alveolar recruitment status of the lung during intraoperative mechanical ventilation.
Trial Registration Number:
DRKS00004286.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.