Cost-effectiveness analysis of a low-cost bubble CPAP device in providing ventilatory support for neonates in Malawi
Background:
A low-cost bubble continuous positive airway pressure (bCPAP) device has been shown to be an excellent clinical alternative to nasal oxygen for the care of neonates with respiratory difficulty. However, the delivery of bCPAP requires more resources than the current routine care using nasal oxygen. We performed an economic evaluation to determine the cost-effectiveness of a low-cost bCPAP device in providing ventilatory support for neonates in Malawi.
Methods:
We used patient-level clinical data from a previously published non-randomized controlled study. Economic data were based on the purchase price of supplies and equipment, adjusted for shelf life, as well as hospital cost data from the World Health Organization. Costs and benefits were discounted at 3%. The outcomes were measured in terms of cost, discounted life expectancy, cost/life year gained and net benefits of using bCPAP or nasal oxygen. The incremental cost-effectiveness ratio and incremental net benefits determined the value of one intervention compared to the other. Subgroup analysis on several parameters (birth weight categories, diagnosis of respiratory distress syndrome, and comorbidity of sepsis) was conducted to evaluate the effect of these parameters on the cost-effectiveness.
Results:
Nasal oxygen therapy was less costly (US$29.29) than the low-cost bCPAP device ($57.78). Incremental effectiveness associated with bCPAP was 6.78 life years (LYs). In the base case analysis, the incremental cost-effectiveness ratio for bCPAP relative to nasal oxygen therapy was determined to be $4.20 (95% confidence interval, US$2.29-US$16.67) per LY gained. The results were highly sensitive for all tested subgroups, particularly for neonates with birth weight 1- < 1.5 kg, respiratory distress syndrome, or comorbidity of sepsis; these subgroups had a higher probability that bCPAP would be cost effective.
Conclusion:
The bCPAP is a highly cost-effective strategy in providing ventilatory support for neonates in Malawi.
More Related Videos
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings