Related Experiment Video
Updated: Apr 20, 2026

A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
11C-methionine PET/CT after inconclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary
U Braeuning, C Pfannenberg, B Gallwitz
1Prof. Dr. Roland Bares, Department Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Otfried-Mueller-Str. 14, 72076 Tuebingen, Germany.
Aim:
To investigate the efficacy of PET/CT with 11C-methionine for localizing parathyroid adenomas in patients with suspected primary hyperparathyroidism and inconclusive results of cervical ultrasonography and 99mTc-MIBI-SPECT/CT.
Patients, Method:
Retrospective analysis of imaging data of 18 patients and correlation with clinical outcome, in particular intraoperative findings and histopathology of excised tissue.
Results:
12 of 18 patients received surgery. In 10 patients single parathyroid adenomas were found (diameter: 5-20 mm), 2 patients presented parathyroid hyperplasia (5 excised hyperplastic glands (diameter: 2-12 mm). PET/CT correctly localized all adenomas and 1 of 5 hyperplastic glands. The sensitivity per patient was 91.7% (11 of 12), the sensitivity per lesion 73.3% (11 of 15). All lesions missed by PET/CT had a size smaller than 9 mm and a volume of less than 0.2 ml. In 6 patients no surgery was performed. Five of them had a negative or atypical PET/CT. Further follow-up indicated familial hypocalciuric hypercalcemia in 3 of them (thus, PET/CT true negative), in the remaining 2 patients no validation is available. One patient with 2 highly suggestive lesions rejected surgery so far.
Conclusion:
PET/CT with 11C-methionine is a very sensitive method for the detection of parathyroid adenomas, even if they are too small to be visualized by 99mTc-MIBI-SPECT/CT.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET