Related Experiment Video
Updated: Apr 20, 2026

Single Port Donor Nephrectomy
Published on: March 12, 2011
Hybrid technique using a Satinsky clamp for right-sided transperitoneal hand-assisted laparoscopic donor nephrectomy:
Bum Soo Kim1, Ki Ho Kim2, Eun Sang Yoo1
1Department of Urology, School of Medicine, Kyungpook National University, Daegu, Korea.
Objective:
To introduce our hybrid technique using a Satinsky clamp for right-sided hand-assisted laparoscopic donor nephrectomy (HALDN) and to compare its effectiveness and safety with those of standard left-sided HALDN.
Methods:
We conducted a retrospective analysis of 253 patients, who underwent HALDN (51 right and 202 left) from January 2003 to December 2012. Perioperative outcomes including operative time, estimated blood loss, warm ischemic time, hospital stay, complications, and recovery of renal function in recipients were collected and compared between the right hybrid HALDN (rhHALDN) and left-sided HALDN groups.
Results:
The procedure was performed successfully in all 253 patients. No statistical difference in the mean operation time (224.3 vs 217.5 minutes), estimated blood loss (128.1 vs 123.6 mL), warm ischemic time (3.3 vs 3.1 minutes), average time to oral intake (2.4 vs 2.1 days), and mean hospital stay (4.9 vs 5.5 days) was observed between the rhHALDN and left-sided HALDN groups (P >.05). Perioperative complication rates were not statistically different between rhHALDN (2 intraoperative, 3 postoperative; 9.8%) and left-sided HALDN (6 intraoperative, 22 postoperative; 13.9%) group (P = .328). No significant difference in mean serum creatinine level and glomerular filtration rate in recipients from postoperative day 1 to 1 year was observed between the 2 groups.
Conclusion:
The perioperative outcomes of rhHALDN using a Satinsky clamp were comparable with those of the left-sided standard HALDN. This hybrid technique can be a technically safe and feasible option for minimally invasive organ donation when right kidney donation is indicated.