Related Experiment Video
Updated: Apr 20, 2026

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Electrochemical determination of low levels of uranyl by a vibrating gold microelectrode
1The Institute of Chemistry, the Hebrew University of Jerusalem , Jerusalem 9190401, Israel.
Abstract:
In this work we report the sensitive electroanalytical detection of uranium(VI) in aqueous solutions. Uranium commonly exists in aqueous solutions in the form of its oxo ion, uranyl (U(VI)O2(2+)). The detection of uranyl has been accomplished by us through its deposition upon reduction by two electrons to the insoluble UO2 using a bare disk gold macroelectrode and anodic stripping voltammetry (ASV). This gave an unsatisfactory detection limit of ca. 1 × 10(-5) M uranyl. Moreover, the evolution of hydrogen bubbles blocked the electrode surface as a result of water reduction at negative deposition potential (-0.7 V vs Ag/AgCl). The application of a 25 μm diameter Au microwire electrode on which UO2 precipitated at negative potential (-1.2 V) improved substantially the detection limit. Further improvement was accomplished by vibrating the microwire working electrode, which increased the amounts of UO2 deposition due to decreasing the diffusion layer. The effect of the vibrating amplitude and frequency on the electroanalytical response was studied and optimized. Eventually, a detection limit of ca. 1 × 10(-9) M uranyl was achieved using a 5 min deposition time, -1.2 V deposition potential, and vibrating the electrode at frequency of 250 Hz and amplitude of 6 V.
More Related Videos
10:02Quantitative SERS Detection of Uric Acid via Formation of Precise Plasmonic Nanojunctions within Aggregates of Gold Nanoparticles and Cucurbit[n]uril
Published on: October 3, 2020
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Electrogravimetric Analysis: Overview
To test the completeness of the...
Microbial Bioremediation of Uranium
Electrodeposition
Electrodeposition can...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Microbial Leaching