Duodenal perforation by an inferior vena cava filter in a polyarteritis nodosa sufferer
Anthony Dat1, Andrew McCann2, John Quinn3
1Department of Surgery, The Alfred Hospital, 55 Commercial Road, Melbourne 3004, Australia.
Introduction:
Inferior vena cava (IVC) filters are currently used in the management of pulmonary embolism (PE) and lower limb venous thromboembolism (VTE). Despite their widespread use, associated complications including duodenal perforation have been reported.
Presentation Of Case:
We describe a unique case of duodenal perforation 2 years post IVC filter insertion in a patient with polyarteritis nodosa (steroid dependent) and thrombocytopenia secondary to chronic cyclophosphamide use.
Discussion:
IVC filters are commonly employed in the management of VTE. Associated complications have been reported including filter migration, fracture and adjacent organ perforation. There is growing consensus that temporary IVC filters should be retrieved as soon as possible with dedicated IVC filter registries to ensure patients are not lost to follow-up post insertion.
Conclusion:
Duodenal perforation is a rare complication of IVC filter insertion. This case however illustrates the potentially catastrophic consequences of a relatively common endovascular procedure. Caution should be taken when considering the insertion of IVC filters in patients with longstanding vasculopathies who are on immunosuppressants.
More Related Videos
Related Concept Videos
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Venous Thrombosis III: Interprofessional Care
Peptic Ulcer
Hemodialysis I: Introduction