Related Experiment Video
Updated: Apr 20, 2026

09:14
Establishment of a Novel Ex Vivo Lung Perfusion System for Rat Lungs After Circulatory Death
Published on: October 18, 2024
1.3K
Successful lung transplantation after donor lung reconditioning with urokinase in ex vivo lung perfusion system
Ilhan Inci1, Yoshito Yamada1, Sven Hillinger1
1Department of Thoracic Surgery, University Hospital, Zurich, Switzerland.
The Annals of Thoracic Surgery
|December 3, 2014
Abstract:
Acute pulmonary embolism is considered a contraindication to lung donation for transplantation as it might result in graft dysfunction. Ex vivo lung perfusion (EVLP) is a novel method to assess and recondition a questionable donor graft before transplantation. In this report we present a case of successful bilateral lung transplant after donor lung assessment and treatment with a fibrinolytic agent, urokinase, during EVLP.