Purpose:
To describe the performance of the nation's hospitals in terms of the Hospital Outpatient Quality Reporting Program's imaging efficiency measures.
Methods:
Data were obtained from the Hospital Compare website and reflect outpatient Medicare claims of 4,118 hospitals for 5 imaging efficiency metrics: (1) frequency of combination abdominal CT (performed with and without intravenous contrast); (2) combination chest CT (performed with and without intravenous contrast); (3) simultaneous brain/sinus CT; (4) mammography follow-up (diagnostic imaging after screening mammography); and (5) lumbar spine MRI for low back pain without prior conservative therapy. Metrics were summarized and compared with other hospital characteristics.
Results:
Median frequency was 36.7% for lumbar spine MRI for low back pain and ranged from 1.6% to 7.8% for the remaining measures; however, extreme outliers were observed (maximal frequencies of 79.2%-95.2% for mammography follow-up and combination chest and abdominal CT). Essentially no correlation was found among measures, aside from combination abdominal and chest CT. For some measures, relatively poor performance was more commonly observed among critical access hospitals and physician-owned/proprietary hospitals, and less commonly observed among U.S. News & World Report "best" hospitals and primary residency teaching sites. Frequencies for combination abdominal and chest CT improved from 2013 to 2014 among hospitals with relatively poorer performance.
Conclusions:
Although the imaging efficiency measures help identify individual hospitals and hospital categories with relatively inefficient imaging practices, they do not readily identify distinctly positively performing hospitals. Excess utilization was suggested for lumbar spine MRI. Frequency of combination abdominal and chest CT examinations improved over a short time interval.
More Related Videos
05:33Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System
Published on: July 11, 2025
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Hospitals-II
Nurses that work in...
Hospitals-I
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...