Related Experiment Video
Updated: Apr 20, 2026

Experimental Methods for Trapping Ions Using Microfabricated Surface Ion Traps
Published on: August 17, 2017
Space charge frequency shifts of the cyclotron modes in multi-species ion plasmas
M Affolter1, F Anderegg, C F Driscoll
1Department of Physics, University of California at San Diego, La Jolla, CA, 92093, USA, maffolter@physics.ucsd.edu.
Abstract:
Shifts of the cyclotron frequency away from the "bare" cyclotron frequency are observed to be proportional to the total ion density through the E × B rotation frequency, and to the relative concentration of each ion species, in quantitative agreement with analytic theory. These shifts are measured at small excitation amplitudes on the typical center-of-mass m = 1 mode, and also on cyclotron modes with m = 0 and m = 2 azimuthal dependence. The frequency spacing between these modes is proportional to the rotation frequency of the ion cloud, which is controlled and measured using a "rotating wall" and laser-induced fluorescence. These cylindrical ion plasmas consist of Mg(+) isotopes, with H3 O (+) and O2 (+) impurities. It is observed that the shift in the m = 1 cyclotron frequency is larger for the minority species (25)Mg(+) and (26)Mg(+), than for the majority species (24)Mg(+). A simple center-of-mass model is presented, which is in quantitative agreement with these results. It is also shown that this model interprets and expands the intensity dependent calibration equation, (M/q) = A/f + B/f (2) + CI/f (2).
More Related Videos
07:17Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
Published on: August 1, 2017
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
Related Concept Videos
Mass Analyzers: Common Types
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Magnetic Field due to Moving Charges
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...
Motion Of A Charged Particle In A Magnetic Field
Continuous Charge Distributions
The electric charge can also be subjected to an analogical...
Ampere-Maxwell's Law: Problem-Solving
To solve the problem, we can use the equations from the analysis of an RC circuit and Maxwell's version of Ampère's law.
For the first part of the...