Related Experiment Video
Updated: Apr 20, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Accuracy of prostate measurements on MRI with and without an endorectal coil
Victoria Chernyak1, Milana Flusberg1, Teodora Kurteva2
1Department of Radiology, Montefiore Medical Center.
Purpose:
To assess accuracy of prostate measurements with and without endorectal coil (ERC).
Materials And Methods:
Anteroposterior (AP), transverse (TX) and craniocaudal (CC) measurements were recorded from 49 prostate magnetic resonance images (MRIs) done both with and without ERC. Prostate weight was calculated as follows: AP*TX*CC*π/6. Prostate dimensions and weight were obtained from radical prostatectomy pathology report.
Results:
After ERC placement, AP decreased by 0.71 cm [95% confidence interval (CI) 0.80-0.61], TX and CC increased by 0.26 cm (95% CI 0.18-0.33) and 0.25 cm (95% CI 0.16-0.35), respectively. Agreement between weight on pathology and MR was excellent: intraclass correlation coefficient (ICC) without ERC=0.96, ICC with ERC=0.90.
Conclusion:
Although ERC distorts measurements and despite a tendency to underestimate the prostate weight, absolute agreement between prostate weight on pathology and MRI is excellent, both with and without ERC.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI