Related Experiment Video
Updated: Apr 20, 2026

Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
Method development for the separation of monoclonal antibody charge variants in cation exchange chromatography, Part
Szabolcs Fekete1, Alain Beck2, Jenő Fekete3
1School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Boulevard d'Yvoy 20, 1211 Geneva 4, Switzerland.
The cation exhange pH gradient approach was evaluated for the characterization of 10 model monoclonal antibodies including panitumumab, natalizumab, cetuximab, bevacizumab, trastuzumab, rituximab, palivizumab, adalimumab, denosumab and ofatumumab. This work shows that retention and resolution can be modelled in cation exchange pH gradient mode, based on only four initial runs (i.e. two gradient times and two mobile phase temperature). Only 6h were required for a complete method optimization when using a 100 mm × 4.6 mm strong cation exchange column. The accuracy of the predictions was excellent, with an average difference between predicted and experimental retention times of about 1%. The 10 model antibodies were successfully eluted in both pH and salt gradient modes, proving that both modes of elution can be considered as multi-product charge sensitive separation methods. For most of the compounds, the variants were better resolved in the salt gradient mode and the peak capacities were also higher in the salt gradient approach. These observations confirm that pH gradient approach may be of lower interest than salt gradient cation exchange chromatography for antibody characterization.
The cation exhange pH gradient approach was evaluated for the characterization of 10 model monoclonal antibodies including panitumumab, natalizumab, cetuximab, bevacizumab, trastuzumab, rituximab, palivizumab, adalimumab, denosumab and ofatumumab. This work shows that retention and resolution can be modelled in cation exchange pH gradient mode, based on only four initial runs (i.e. two gradient times and two mobile phase temperature). Only 6h were required for a complete method optimization when using a 100 mm × 4.6 mm strong cation exchange column. The accuracy of the predictions was excellent, with an average difference between predicted and experimental retention times of about 1%. The 10 model antibodies were successfully eluted in both pH and salt gradient modes, proving that both modes of elution can be considered as multi-product charge sensitive separation methods. For most of the compounds, the variants were better resolved in the salt gradient mode and the peak capacities were also higher in the salt gradient approach. These observations confirm that pH gradient approach may be of lower interest than salt gradient cation exchange chromatography for antibody characterization.
More Related Videos
10:41Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
10:50Purification and Analytics of a Monoclonal Antibody from Chinese Hamster Ovary Cells Using an Automated Microbioreactor System
Published on: May 1, 2019
Related Concept Videos
Ion-Exchange Chromatography
Ion Exchange
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Affinity Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...