Time-dependent responses to provocative testing with flecainide in the diagnosis of Brugada syndrome
David Calvo1, José M Rubín1, Diego Pérez1
1Arrhythmia Unit, Cardiology Department.
Background:
Time-dependent variability of electrocardiogram (ECG) in patients with Brugada syndrome could affect the interpretation of provocative testing.
Objective:
The aim of this study was to characterize ECG changes during and after flecainide infusion.
Methods:
We studied 59 consecutive patients. The ECG was continuously analyzed during the first 30 minutes of provocative testing, and a single ECG was recorded 60 minutes later. We analyzed CYP2D6 and CYP3A5 variants affecting flecainide metabolism and performed blinded measurements at lead II.
Results:
At baseline, ECG patterns were classified as follows: type II in 31 patients (53%), type III in 15 (25%), and normal ECG in 13 (22%). Because of induction of type I ECG, the percentage of responders progressively increased with longer recording time periods (6.8% in 10 minutes vs 11.9% in 20-30 minutes vs 18.6% in 90 minutes; P < .01). Four patients displayed a late response, which was evidenced 90 minutes after the initiation of provocative testing. QRS width differentially increased between responders and nonresponders (P < .01), with a maximum QRS width of 110 ms during the first 30 minutes being effective for identifying possible late responders (sensitivity 100%; specificity 85.6%; positive predictive value 88%; negative predictive value 100%). The incidence of CYP2D6 variants was lower in late responders than in early or delayed responders (0% vs 75% vs 100%; P = .04), while a homogeneous distribution of CYP3A5*3/*3 was observed in our population.
Conclusion:
Response to flecainide exhibits time-dependent variability of ECG patterns and intervals. Longer periods of ECG recording increase the recognition probability of type I ECG.
More Related Videos
10:41Laser-Induced Action Potential-Like Measurements of Cardiomyocytes on Microelectrode Arrays for Increased Predictivity of Safety Pharmacology
Published on: September 13, 2022
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...